Problem Solution
Wrong Display Price
  1. Locate & Press mode on control panel. HD will show on display
  2. Hold button 1 & 2 simultaneously until you see SP on display.
  3. Press and hold 1 down to increase the price. Press 1 and then repress and hold to decrease price.
Vendor Continuously Changes Prices.
  1. Set Prices on machine correctly. (Refer to Wrong Display Price)
  2. After prices have been set close door.
  3. Check for correct prices.
  4. Unplug machine for aproximately 30 seconds
  5. Replug machine in.
  6. If Vendor does not retain price replace battery on board and repeat step 1-5.
  7. If price is still not correct replace board.
Takes money and when you push a selection you get your money back only.
  1. Unplug vendor.
  2. Remove cover from board.
  3. Test fuses on the board.
  4. Replace bad fuse.
  5. Test vend.
Takes money and when you select a product displays says sold out on a certain row.
  1. Make sure the row is full.
  2. Remove the motor cover.
  3. Make sure all motor switches are in a notch on the cam by the motors.
  4. Remove all the product from the row that do not have a switch in the notch of the cam.
  5. Unjam the row.
  6. Refill the row.
  7. Test Vend.
Set Display Price
  1. Locate & Press mode on control panel. HD will show on display
  2. Hold button 1 & 2 simultaneously until you see SP on display.
  3. Press and hold 1 down to increase the price. Press 1 and then repress and hold to decrease price.
Install And Remove Door Switch
  1. Disconnect wires leading to machine.
  2. Squeeze together the tabs on the door switch to remove.
  3. Put fittings and crimp the wires that led to the old switch.
  4. Attach wires to the new switch.
  5. Squeeze together the tabs on the new switch and push it into the slot.
  6. Make sure that the new switch is mounted the same way as the old switch.
Install And Remove Compressor
  1. Open Vendor Door.
  2. Take out can tray.
  3. Remove the guards.
  4. Take out bolts holding compressor down.
  5. Slide out compressor(carefull not to kink any lines).
    1. Make sure compressor is unplugged.
  6. Slide in new compressor.
    1. Take the cord from the compressor and plug it into the lower lefthand of the machine.
    2. Replace the guards around the condenser.
  7. Make sure none of the lines are pinched and the fan can spin freely.
  8. Make sure the cold control is fastened by the evaporator.
    1. The cold control should be set at either 3 or 4.
  9. Reinstall the can tray.
  10. Close machine door.
  11. Wait for compressor to start.